- Revised VTS Protocols (Effective 1 August 2024)
- AIS Transponder Requirements:
- Continuous AIS transmission required from 20nm approaching waypoint WP-33 (22°25’N 113°52’E)
- USD 8,000 penalty for AIS outages >15 minutes during transit
- New Traffic Separation Schemes:
- Lingdingyang TSS Sector 2 revised with 0.5nm widening (Now 1.8nm between lanes)
- Mandatory starboard passage at Humen Bridge (West span prohibited for vessels >150m LOA)
- AIS Transponder Requirements:
- Enhanced Pilotage Requirements
- Night Navigation Restrictions:
- VLCCs >280m LOA prohibited from entering Dayushan anchorage 2200-0500 LT
- Fog procedures activated when visibility <1nm: 50% speed reduction + mandatory radar overlay
- Pilot Transfer Safety:
- Mandatory pilot ladder illumination (10 lux minimum at boarding point)
- New boarding buoys deployed at 22°31’18″N 113°47’42″E (MEIDI-7 buoy) with 24/7 monitoring
- Night Navigation Restrictions:
- Cargo Handling Mandates
- Bulk Cargo Precautions:
- Coal cargoes must maintain ≤12% moisture content (GNZY-2024 test certificate required)
- Iron ore pile height restricted to 15m at Xinsha Bulk Terminal (GB/T 37154-2023 stacking rules)
- Container Securing Rules:
- Twist lock inspection every 24hr during extended stays (Certified third-party reports accepted)
- Mandatory lashing for empty containers ≥6 high in Bay 80-01 to 82-12
- Bulk Cargo Precautions:
- Terminal Operating Limits
- Grain Terminal J5:
- Max suction rate 800t/hr with dust suppression activated
- Prohibition of simultaneous loading/unloading in adjacent holds
- Nansha Ro-Ro Terminal:
- Vehicle deck temperature monitoring required (Max 60°C during summer operations)
- Emergency steering gear test within 6hr prior to berthing
- Grain Terminal J5:
- Sanitation & Health Controls
- Medical Waste Handling:
- Yellow biomedical bags (GB 19217-2024 compliant) required for onboard disposal
- 24hr collection service: VHF Ch 14 or +86-20-8222-0917
- Pest Control:
- Mandatory pre-departure fumigation for vessels docking at Grain Terminal ≥72hr
- USD 15,000 fine for rat presence during inspections
- Medical Waste Handling:
- Emerging Security Requirements
- Cyber Protection:
- Mandatory ECDIS Type Approval Certificate (IEC 61174 Ed.5) for all berthing vessels
- Prohibition of USB connections to critical systems during port stay
- Cyber Protection:
- Technical Service Directives
- Bunkering Specifications:
- 0.10% sulfur fuel verification via mass spectrometry (ISO 4259-2024 method)
- Mandatory cooling of IFO380 to ≤40°C before transfer
- Bunkering Specifications:
- Emergency Response Updates
- Oil Spill Readiness:
- Pre-registered spill kits required: 200L capacity per 1,000 GT
- MSA verification via surprise drills (15-minute deployment test)
- Oil Spill Readiness:
Supplemental Operational Directives
Terminal | New Requirement | Effective Date |
---|---|---|
Xinhai Container Terminal | RMG crane anti-collision system (GB/T 41120-2024) | 1 Nov 2024 |
Zhuhai LNG Terminal | Gas detection calibration every 20 minutes | Immediate |